LGDRYER

LG · Tumble dryer

LG PS error code

Wrong voltage at the power cord

The dryer is getting the wrong voltage through its power cord. LG says the white and red wires may be the wrong way round on the terminal block at the back.

Worth repairing?

Worth fixing

Often a wiring mistake at the cord, which is quick to put right. Have it checked before you keep using the dryer.

Got a quote? Check if it's worth paying

Can you do it yourself?

Engineer only

1 minute to reset the breaker

Before you start

  • Unplug it before you touch anything inside.
  • Power cord wiring is mains work: breaker off, and leave it to a qualified electrician.

What to check, in order

  1. Check the plug

    The cord should be firmly in a grounded outlet that matches the dryer's rating plate: 240 V.

  2. Reset the breaker

    Turn the dryer's circuit breaker off for at least 10 seconds, then back on.

  3. Check the cord wiring

    LG says to check how the power cord is connected at the back of the dryer. It has installation videos for 3-wire and 4-wire cords. This is mains wiring, so have an electrician do it if you're not qualified.

When to call an engineer

If the cord is wired correctly and PS stays, LG says the dryer needs service.

A repair visit will usually check the supply at the socket, the plug and the machine's power input.

Before you book
  • Note the model and serial number. They're on a label inside the door, around the door frame or on the back.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.

Checked against

Last reviewed September 2026. Manufacturers update their pages, and your manual is the final word.