Baxi error codes

Baxi gas boilers show a code on the display when they stop. The Duo-tec, Platinum, EcoBlue, Assure, Megaflo, Main Eco and Baxi 600 and 800 Combi and System boilers use E and a number, such as E133 or E118. The newer Baxi 200, 400, 600 and 800 Combi 2 and System 2 boilers use a longer format, such as H.02.07. Some displays split a code in two: Baxi says E133 alternates between E1 and 33.

  • 16 codes
  • Boilers
  • Checked against official pages
BAXIBOILER

Boilers 16 codes

E133 Won't light: gas supply or frozen pipe

The boiler tried to light and couldn't, so it has locked out.

Worth fixing

E119 Shut down: condensate pipe may be frozen

Baxi's help pages list E119 among the codes a boiler shows when it has shut down because its condensate pipe may be frozen.

Usually free

E118 Water pressure too low

Baxi lists E118 as low water pressure: below 0.5 bar in the heating system.

Usually free

H.02.07 Water pressure too low (newer models)

The water pressure in the heating circuit is too low.

Usually free

E128 Flame keeps going out

The boiler has locked out because it lost its flame too often.

Worth fixing

E125 Water isn't circulating

Baxi lists E125 as a water circulation fault.

Get a quote first

E110 Overheated and shut down

The boiler got too hot and a safety cut-out stopped it.

Get a quote first

E160 Fan fault

Baxi lists E160 as a fan fault.

Get a quote first

E20 Heating temperature sensor fault

The sensor that measures the heating water temperature, or its wiring, has failed, so the boiler has stopped for safety.

Worth fixing

E28 Flue sensor fault, or blocked flue or condensate

Baxi lists E28 as a flue temperature sensor fault, and its Platinum user guide adds that it can mean a blocked flue or condensate drain.

Usually free

E50 Hot water temperature sensor fault

The sensor that measures the hot water temperature has failed or isn't connected properly.

Worth fixing

E117 Water pressure too high

The pressure in the heating system has gone too high, so the boiler has stopped.

Get a quote first

E130 Flue overheat: safety sensor tripped

The flue gases got too hot and a safety sensor has locked the boiler out.

Get a quote first

E135 Gas supply interrupted

The boiler lost its gas supply, or found an internal fault, and stopped.

Usually free

E151 Flame failure

The burner flame failed or wasn't detected, so the boiler stopped.

Usually free

H.01.18 Water isn't circulating (temporary)

Water isn't moving through the boiler properly.

Usually free

No codes of that type for this brand.

Good to know

  • If you smell gas, call the gas emergency number, 0800 111 999. Baxi's advice is to open doors and windows, turn the gas off at the meter unless it's in a cellar or basement, and not use electric switches or naked flames.
  • Baxi says the water pressure should be between 1 and 2 bar. Its winter advice gives 1 to 1.5 bar.
  • Baxi's reset advice: if the boiler locks out often, that means there's a fault, and you should contact your installer or a service engineer.
  • Baxi's code list for engineers also covers Potterton Assure Combi and System boilers.
  • Baxi's frost advice lists E28 among the codes a frozen condensate pipe can cause, while its list for engineers gives E28 as a flue temperature sensor fault. If the weather isn't cold, don't assume the pipe is frozen.
  • Baxi's PDF user guides used here were read in a web browser, because they block automated downloads.

Official help pages

Every code page links the exact pages it was checked against. Last reviewed October 2026.

Another code on the display?

Look it up in seconds

344 codes from 24 brands, each one checked against the maker's own manuals and support pages.

↑ ↓ to moveEnter to openTip: add the brand, like samsung 4e