Boiler pressure too low

A combi or system boiler needs the heating water topped up to a set pressure. When it drops too low, the boiler shuts down to protect itself and shows a code. Topping it up is usually a five-minute job.

  • 12 codes
  • 4 brands
  • Often easy to fix

The code on each brand

Same fault, different code. Each one opens a page with the maker's own checks and a verdict.

Can't read yours?

Worcester Bosch 1017 System pressure too low

The water pressure in your heating system is too low.

Usually free

Worcester Bosch A1 Pump has run dry

The boiler's pump has been running without enough water in the system, so the boiler has locked out.

Worth fixing

Worcester Bosch CE 207 System water pressure too low

The heating system has lost water pressure.

Usually free

Worcester Bosch 2964 Water flow through the boiler too low

Not enough water is flowing through the boiler's heat exchanger.

Usually free

Vaillant F22 Low water pressure

The water pressure in your heating system has dropped too low, so the boiler has shut down for now.

Usually free

Vaillant F75 No pressure rise when the pump starts

When the boiler's pump started, the pressure didn't change as much as it should.

Get a quote first

Vaillant F83 Not enough water when the burner lit

When the burner lit, the boiler's temperature sensors saw almost no change.

Usually free

Baxi E118 Water pressure too low

Baxi lists E118 as low water pressure: below 0.5 bar in the heating system.

Usually free

Baxi H.02.07 Water pressure too low (newer models)

The water pressure in the heating circuit is too low.

Usually free

Baxi E117 Water pressure too high

The pressure in the heating system has gone too high, so the boiler has stopped.

Get a quote first

Baxi H.01.18 Water isn't circulating (temporary)

Water isn't moving through the boiler properly.

Usually free

Ideal F1 Water pressure too low

The water pressure in the heating system is too low.

Usually free

Check these first, whatever the brand

  1. Read the gauge when the heating is cold

    Pressure rises as the water warms up, so check it with the heating off and the boiler cool. Many boilers want about 1 to 1.5 bar; your manual gives the exact range.

  2. Top it up with the filling loop

    Follow your boiler's manual: open the filling loop valves slowly, watch the gauge, and close them fully when it reaches the right pressure. Don't go past the maker's figure.

  3. Reset the boiler

    Once the pressure is back up, reset the boiler the way your manual describes.

  4. Bled a radiator recently?

    Bleeding radiators lets air out and lowers the pressure, so a top-up afterwards is normal.

  5. Look for a leak

    If it keeps dropping, check radiators, valves and the pipes under the boiler for drips. Also look at the small pressure relief pipe outside: if it drips, the boiler is letting water out.

When it's time for an engineer

If you have to top up more than now and then, something is losing water. A Gas Safe engineer will check the expansion vessel, the pressure relief valve and the system for leaks.

Parts people end up buying

Only once the checks point to a part. Match it to your model number: it's on a label on the data badge, usually under the boiler or behind the front cover.

Affiliate links: as an Amazon Associate I earn from qualifying purchases, at no extra cost to you. It never changes a verdict.

Questions people ask

What should my boiler pressure be?

Most boilers want about 1 to 1.5 bar when the system is cold, but check your manual: some makers give a wider range.

Why does my boiler keep losing pressure?

Usually a small leak somewhere in the system, or a fault with the expansion vessel or the pressure relief valve. If you're topping up often, have it checked.