DAIKINAC

Daikin · Air conditioner

Daikin A6 error code

Indoor fan motor fault

The fan inside the indoor unit is not turning at the speed the control board expects, or not turning at all, so the unit has stopped.

What to check

Checked against 4 official sourcesReviewed October 2026

Worth repairing?

Get a quote first

Usually a new fan motor or indoor control board. Get a quote first.

Got a quote? Check if it's worth paying

Can you do it yourself?

Engineer only

Engineer visit

Before you start

  • Unplug it before you touch anything inside.

What it means

Daikin's US service manual calls it a fan motor (DC motor) or related abnormality. It is flagged when the fan stays below half its maximum speed, or does not turn for more than 5 seconds after starting.

What to check, in order

  1. Switch off at the breaker

    Turn the unit off and switch off the air conditioner's own circuit breaker for 20 minutes, as Daikin's troubleshooting page describes.

  2. Look for anything in the air outlet

    With the power off, check the air outlet for anything that could stop the fan turning. Don't take the casing apart.

  3. Restart with the remote

    Switch the breaker back on and restart. If the operation lamp flashes again, book an engineer.

When to call an engineer

Daikin's service manual lists a large drop in supply voltage, a broken or shorted fan motor winding, broken motor lead wires and a faulty indoor control board. An engineer checks the connector and whether the fan turns freely, then replaces the motor or the board.

A repair visit will usually check the fan motor, its wiring and anything blocking the blades.

Before you book
  • Note the model and serial number. They're on a label on the side of the indoor unit, and on the outdoor unit.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.

Quick answers

What does the Daikin A6 error code mean?

The fan inside the indoor unit is not turning at the speed the control board expects, or not turning at all, so the unit has stopped. Daikin's US service manual calls it a fan motor (DC motor) or related abnormality. It is flagged when the fan stays below half its maximum speed, or does not turn for more than 5 seconds after starting.

Can I fix Daikin A6 myself?

Engineer only (engineer visit). Start with: switch off at the breaker; look for anything in the air outlet; restart with the remote. Daikin's service manual lists a large drop in supply voltage, a broken or shorted fan motor winding, broken motor lead wires and a faulty indoor control board. An engineer checks the connector and whether the fan turns freely, then replaces the motor or the board.

Is Daikin A6 worth repairing?

Get a quote first. Usually a new fan motor or indoor control board. Get a quote first.

Checked against

Last reviewed October 2026. Manufacturers update their pages, and your manual is the final word. Spotted a mistake? Email contact@appliance-error-codes.com.