Daikin · Air conditioner

Daikin E6 error code

Compressor lock

The compressor did not start turning when the control board tried to start it, so the system has stopped.

What to check

Checked against 3 official sourcesReviewed October 2026

Worth repairing?

Get a quote first

If the compressor itself has seized it is a big job. On an older system, compare the quote with the cost of a new unit.

Got a quote? Check if it's worth paying

Can you do it yourself?

Engineer only

Engineer visit

Before you start

  • Unplug it before you touch anything inside.
  • Sealed refrigerant system: engineer only.

What it means

Daikin's US service manual says it detects a locked compressor from the current waveform when it applies high-frequency voltage to the motor. The system shuts down if the error keeps repeating, and Daikin gives the reset condition as about 11 minutes of continuous running without any other error.

What to check, in order

  1. Reset at the breaker

    Switch off the air conditioner's own breaker for 20 minutes, then switch on and restart with the remote.

  2. Mention a recent install

    Daikin lists a closed stop valve as a cause. Tell the engineer if the unit is new or was recently moved.

When to call an engineer

Daikin's service manual lists a closed stop valve, a locked compressor and a disconnected compressor harness. An engineer tests the outdoor control board with an inverter analyser before condemning the compressor, which Daikin's flowchart replaces if the fault keeps returning.

A repair visit will usually check the compressor, its wiring and the inverter board that drives it.

Before you book
  • Note the model and serial number. They're on a label on the side of the indoor unit, and on the outdoor unit.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.

Quick answers

What does the Daikin E6 error code mean?

The compressor did not start turning when the control board tried to start it, so the system has stopped. Daikin's US service manual says it detects a locked compressor from the current waveform when it applies high-frequency voltage to the motor. The system shuts down if the error keeps repeating, and Daikin gives the reset condition as about 11 minutes of continuous running without any other error.

Can I fix Daikin E6 myself?

Engineer only (engineer visit). Start with: reset at the breaker; mention a recent install. Daikin's service manual lists a closed stop valve, a locked compressor and a disconnected compressor harness. An engineer tests the outdoor control board with an inverter analyser before condemning the compressor, which Daikin's flowchart replaces if the fault keeps returning.

Is Daikin E6 worth repairing?

Get a quote first. If the compressor itself has seized it is a big job. On an older system, compare the quote with the cost of a new unit.

Checked against

Last reviewed October 2026. Manufacturers update their pages, and your manual is the final word. Spotted a mistake? Email contact@appliance-error-codes.com.