Overheated and shut down

The boiler got too hot and a safety cut-out stopped it. Baxi's list for engineers says a jammed pump or air in the circuit is the likely cause.

Worth repairing?

Get a quote first

If it comes back after a reset, the pump may need freeing or replacing. Ask for a price first, especially on an older boiler.

Can you do it yourself?

Engineer only

About 10 minutes to check and reset

Before you start

  • Never take the boiler's cover off. Anything inside is a job for a Gas Safe registered engineer.

What to check, in order

  1. Check the pressure gauge

    Baxi says it should read between 1 and 2 bar. If it's below 1 bar, top it up with the filling loop.

  2. Reset the lockout

    On boilers with a selector switch, turn it to R and hold it there for at least 5 seconds, then let go. If yours has a reset button, press it until the red light goes out. On boilers reset with the temperature control knob, turn it fully anticlockwise, hold it until the red lockout light goes out, then turn it back to your setting.

When to call a Gas Safe engineer

If it overheats again, call a Gas Safe registered engineer. A jammed pump is a job for them.

A repair visit will usually check the pump, the flow of water round the system and the overheat thermostat.

Before you book
  • Note the model and serial number. They're on a label on the data badge, usually under the boiler or behind the front cover.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.