Vaillant aroTHERM F514 error code

Compressor inlet temperature sensor fault

The heat pump is not getting a usable reading from the temperature sensor at the compressor inlet. Vaillant says the sensor is either not connected or its input has short-circuited.

What to check

Checked against 1 official sourceReviewed October 2026

Worth repairing?

Worth fixing

Vaillant's listed causes are the sensor and its wiring, not the compressor itself, so this is normally a routine repair.

Can you do it yourself?

Engineer only

Engineer visit

Before you start

  • Unplug it before you touch anything inside.

What it means

Vaillant's VWZ AI fault table gives the same cause and remedy for its other temperature sensor codes, including F.517 (compressor outlet), F.519 (heating return) and F.520 (heating flow).

What to check, in order

  1. Reset once

    Press the reset button on the control module. If the fault comes back after several resets, Vaillant says to contact Customer Service.

  2. Leave the casing closed

    The sensor is inside the outdoor unit, so this is a job for an engineer.

When to call your installer

Call your installer. Vaillant's remedy is to check the sensor and replace it if necessary, and to replace the wiring harness if needed.

A repair visit will usually check the sensor's reading and its wiring.

Before you book
  • Note the model and serial number. They're on a label on the rating plate on the outdoor unit, and on the indoor unit or cylinder.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.

Quick answers

What does the Vaillant aroTHERM F514 error code mean?

The heat pump is not getting a usable reading from the temperature sensor at the compressor inlet. Vaillant says the sensor is either not connected or its input has short-circuited. Vaillant's VWZ AI fault table gives the same cause and remedy for its other temperature sensor codes, including F.517 (compressor outlet), F.519 (heating return) and F.520 (heating flow).

Can I fix Vaillant aroTHERM F514 myself?

Engineer only (engineer visit). Start with: reset once; leave the casing closed. Call your installer. Vaillant's remedy is to check the sensor and replace it if necessary, and to replace the wiring harness if needed.

Is Vaillant aroTHERM F514 worth repairing?

Worth fixing. Vaillant's listed causes are the sensor and its wiring, not the compressor itself, so this is normally a routine repair.

Checked against

Last reviewed October 2026. Manufacturers update their pages, and your manual is the final word. Spotted a mistake? Email contact@appliance-error-codes.com.

Another code on the display?

Look it up in seconds

344 codes from 24 brands, each one checked against the maker's own manuals and support pages.

↑ ↓ to moveEnter to openTip: add the brand, like samsung 4e