VAILLANTHEAT PUMP

Vaillant · Heat pump

Vaillant aroTHERM F733 error code

Evaporation temperature too low

The refrigerant in the outdoor unit is getting too cold. Vaillant gives two main causes: not enough air passing through the outdoor unit's heat exchanger, or too little refrigerant.

What to check

Checked against 3 official sourcesReviewed October 2026

Worth repairing?

Worth fixing

A blocked outdoor unit is an easy fix. If the refrigerant level is low, an F-gas engineer needs to find out why.

Can you do it yourself?

Easy

About 15 minutes

Before you start

  • Switch the heat pump off at its circuit breaker before you clear leaves or snow, and keep your hands out of the fan grille.
  • Sealed refrigerant system: engineer only.

What it means

In cooling mode the shortage is on the water side instead, and Vaillant's table says to check that any thermostatic valves in the heating circuit are suitable for cooling.

What to check, in order

  1. Check the outdoor unit is clear

    Look for leaves, snow or anything else blocking the grilles. Switch off at the breaker before clearing anything. Vaillant's operating instructions say to keep the air inlet and outlet grilles clear.

  2. Reset once

    Press the reset button on the control module. If the fault keeps coming back, Vaillant says to contact Customer Service.

When to call your installer

If the unit is clear and the fault returns, call your installer. Vaillant's table has them check the fan unit for dirt, the electronic expansion valve, the compressor inlet sensor and the refrigerant charge. Refrigerant work needs an F-gas certified engineer.

Quick answers

What does the Vaillant aroTHERM F733 error code mean?

The refrigerant in the outdoor unit is getting too cold. Vaillant gives two main causes: not enough air passing through the outdoor unit's heat exchanger, or too little refrigerant. In cooling mode the shortage is on the water side instead, and Vaillant's table says to check that any thermostatic valves in the heating circuit are suitable for cooling.

Can I fix Vaillant aroTHERM F733 myself?

Easy (about 15 minutes). Start with: check the outdoor unit is clear; reset once. If the unit is clear and the fault returns, call your installer. Vaillant's table has them check the fan unit for dirt, the electronic expansion valve, the compressor inlet sensor and the refrigerant charge. Refrigerant work needs an F-gas certified engineer.

Is Vaillant aroTHERM F733 worth repairing?

Worth fixing. A blocked outdoor unit is an easy fix. If the refrigerant level is low, an F-gas engineer needs to find out why.

Checked against

Last reviewed October 2026. Manufacturers update their pages, and your manual is the final word. Spotted a mistake? Email contact@appliance-error-codes.com.

Another code on the display?

Look it up in seconds

344 codes from 24 brands, each one checked against the maker's own manuals and support pages.

↑ ↓ to moveEnter to openTip: add the brand, like samsung 4e