MITSUBISHI ELECTRICHEAT PUMP

Mitsubishi Electric · Heat pump

Mitsubishi Ecodan L5 error code

Indoor temperature sensor fault

One of the water temperature sensors (thermistors) connected to the indoor unit is reading as open or short circuit, so the controller can't trust it.

What to check

Checked against 4 official sourcesReviewed October 2026

Worth repairing?

Worth fixing

Mitsubishi lists a loose connection or a faulty sensor first. A control board fault is the costlier possibility.

Can you do it yourself?

Engineer only

Engineer visit

Before you start

  • Unplug it before you touch anything inside.

What it means

Mitsubishi's title is "Indoor unit temperature thermistor ... failure", followed by a list of sensors. The FTC5 manual lists THW1, THW2, THW5 and THW6 to THW9. Later manuals name the tank sensor THW5B, or THW5A and THW5B. The service manual treats a reading of -39°C or below as open and 88.5°C or above as short.

What to check, in order

  1. Write the code down and reset once

    Switch the system off, clear the code at the main remote controller and see if it returns.

  2. Leave the sensors to your installer

    Mitsubishi's action is to check the resistance across the sensor, which means opening the unit. That is an installer job.

When to call your installer

Call your installer. Mitsubishi's service manual lists a loose connector or wire, a faulty sensor, wrong DIP switch settings or a control board fault, and says to compare the sensor's resistance with its table.

A repair visit will usually check the sensor's reading and its wiring.

Before you book
  • Note the model and serial number. They're on a label on the rating plate on the outdoor unit, and on the indoor unit or cylinder.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.

Quick answers

What does the Mitsubishi Ecodan L5 error code mean?

One of the water temperature sensors (thermistors) connected to the indoor unit is reading as open or short circuit, so the controller can't trust it. Mitsubishi's title is "Indoor unit temperature thermistor ... failure", followed by a list of sensors. The FTC5 manual lists THW1, THW2, THW5 and THW6 to THW9. Later manuals name the tank sensor THW5B, or THW5A and THW5B. The service manual treats a reading of -39°C or below as open and 88.5°C or above as short.

Can I fix Mitsubishi Ecodan L5 myself?

Engineer only (engineer visit). Start with: write the code down and reset once; leave the sensors to your installer. Call your installer. Mitsubishi's service manual lists a loose connector or wire, a faulty sensor, wrong DIP switch settings or a control board fault, and says to compare the sensor's resistance with its table.

Is Mitsubishi Ecodan L5 worth repairing?

Worth fixing. Mitsubishi lists a loose connection or a faulty sensor first. A control board fault is the costlier possibility.