DAIKINHEAT PUMP

Daikin · Heat pump

Daikin Altherma AJ-03 error code

Hot water taking too long to heat up

Heating the hot water tank has taken too long, so the heat pump has switched to space heating for a while.

Also shown as AJ

What to check

Checked against 4 official sourcesReviewed October 2026

Worth repairing?

Usually free

After unusually heavy hot water use it clears itself. If it keeps coming back with normal use, a heater, valve or power fault needs checking.

Can you do it yourself?

Very easy

A few minutes

Before you start

  • Low risk: nothing to open up.

What it means

Daikin's guides list it as "Too long DHW heat-up time required". Its service manual gives the trigger as more than 6 hours to heat the tank, after which the unit switches to space heating or cooling for 3 hours.

What to check, in order

  1. Check for heavy hot water use

    Daikin's service manual lists very high hot water use and a leaking hot water tap among the causes. Make sure no hot tap is running or dripping.

  2. Let it reset

    Daikin's installer reference guide says AJ-03 resets automatically as soon as the tank heats up normally again.

When to call your installer

If it keeps happening with normal hot water use, call your installer. Daikin's service manual lists a faulty backup heater, the backup heater not being allowed, power supply problems, a faulty 3-way valve, a faulty hydro PCB, or a software mismatch between the board and the user interface.

Quick answers

What does the Daikin Altherma AJ-03 error code mean?

Heating the hot water tank has taken too long, so the heat pump has switched to space heating for a while. Daikin's guides list it as "Too long DHW heat-up time required". Its service manual gives the trigger as more than 6 hours to heat the tank, after which the unit switches to space heating or cooling for 3 hours.

Can I fix Daikin Altherma AJ-03 myself?

Very easy (A few minutes). Start with: check for heavy hot water use; let it reset. If it keeps happening with normal hot water use, call your installer. Daikin's service manual lists a faulty backup heater, the backup heater not being allowed, power supply problems, a faulty 3-way valve, a faulty hydro PCB, or a software mismatch between the board and the user interface.

Is Daikin Altherma AJ-03 worth repairing?

Usually free. After unusually heavy hot water use it clears itself. If it keeps coming back with normal use, a heater, valve or power fault needs checking.

Checked against

Last reviewed October 2026. Manufacturers update their pages, and your manual is the final word. Spotted a mistake? Email contact@appliance-error-codes.com.

Another code on the display?

Look it up in seconds

344 codes from 24 brands, each one checked against the maker's own manuals and support pages.