DAIKINHEAT PUMP

Daikin · Heat pump

Daikin Altherma AA-01 error code

Backup heater overheated

The electric backup heater in the indoor unit got too hot and its safety cut-out has tripped, so the heat pump has stopped.

Also shown as AA

What to check

Checked against 4 official sourcesReviewed October 2026

Worth repairing?

Worth fixing

Needs an engineer to reset the cut-out and find out why it tripped, which may be a flow or pressure problem rather than the heater itself.

Can you do it yourself?

Engineer only

Engineer visit

Before you start

  • Unplug it before you touch anything inside.
  • Let it cool completely first.

What it means

The Altherma 3 R ECH2O guide words it as "Backup heater overheated or BUH power cable not connected". AA-02 is used when an external backup heater overheats. Daikin's service manual says AA-01 needs a reset at the controller and a manual reset of the backup heater's thermal protector.

What to check, in order

  1. Check the water pressure

    Daikin's service manual lists low water pressure, low water flow and air in the water circuit among the causes. Check the pressure on the home screen is above 1 bar.

  2. Leave the cut-out to your installer

    Daikin's service manual says the backup heater's thermal protector has to be reset by hand as well as at the controller. Leave that to your installer and don't open the unit yourself.

  3. Read the help text

    On the controller, open the main menu and choose Malfunctioning to see the code and a short description. The help button gives a longer one. Note the code for your installer.

When to call your installer

Call your installer, who will find the cause before resetting it. Daikin's service manual lists low water pressure or flow, air in the water circuit, an external heat source, a faulty thermal protector, a faulty outlet water thermistor, a faulty backup heater or a faulty hydro PCB.

A repair visit will usually check the water flow, the valves and the temperature sensors.

Before you book
  • Note the model and serial number. They're on a label on the rating plate on the outdoor unit, and on the indoor unit or cylinder.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.

Quick answers

What does the Daikin Altherma AA-01 error code mean?

The electric backup heater in the indoor unit got too hot and its safety cut-out has tripped, so the heat pump has stopped. The Altherma 3 R ECH2O guide words it as "Backup heater overheated or BUH power cable not connected". AA-02 is used when an external backup heater overheats. Daikin's service manual says AA-01 needs a reset at the controller and a manual reset of the backup heater's thermal protector.

Can I fix Daikin Altherma AA-01 myself?

Engineer only (engineer visit). Start with: check the water pressure; leave the cut-out to your installer; read the help text. Call your installer, who will find the cause before resetting it. Daikin's service manual lists low water pressure or flow, air in the water circuit, an external heat source, a faulty thermal protector, a faulty outlet water thermistor, a faulty backup heater or a faulty hydro PCB.

Is Daikin Altherma AA-01 worth repairing?

Worth fixing. Needs an engineer to reset the cut-out and find out why it tripped, which may be a flow or pressure problem rather than the heater itself.

Checked against

Last reviewed October 2026. Manufacturers update their pages, and your manual is the final word. Spotted a mistake? Email contact@appliance-error-codes.com.