VAILLANTBOILER

Vaillant · Boiler

Vaillant F75 error code

No pressure rise when the pump starts

When the boiler's pump started, the pressure didn't change as much as it should. Low system pressure, the pump or the pressure sensor can cause it.

Also shown as F.075

Worth repairing?

Get a quote first

If the pressure was fine, the fault is a part inside the boiler, such as the pump or the pressure sensor, so ask for a price first.

Can you do it yourself?

Engineer only

10 minutes of checks

Before you start

  • Never take the boiler's cover off. Anything inside is a job for a Gas Safe registered engineer.

What to check, in order

  1. Check the pressure gauge

    Vaillant lists low system pressure and too little water among the causes. With the system cold, its ecoTEC plus manual wants 1.0 to 2.0 bar.

  2. Top up if it's low

    Open the filling loop slowly until the gauge reaches the right pressure, then close it again.

When to call a Gas Safe engineer

If the pressure is fine, or F75 comes back, call a Gas Safe registered engineer. Vaillant lists a faulty pressure sensor, pump or internal expansion vessel, air in the boiler and wiring faults.

A repair visit will usually check the pressure sensor, the pump, the expansion vessel and the pressure relief valve.

Before you book
  • Note the model and serial number. They're on a label on the data badge, usually under the boiler or behind the front cover.
  • Write down the exact code, and what the appliance was doing when it appeared.
  • Check whether it's still under warranty. If it is, the repair may cost you nothing.

Checked against

Last reviewed September 2026. Manufacturers update their pages, and your manual is the final word.